General Specifications
Power supply: 6x AA 1.5V alkaline (LR6)
USB 5.0V
Dimensions: 17 x 9 x 3.3 cm
6.7 x 3.5 x 1.3 inches
Weight: 360g including 6 batteries (18 oz)
Operational and storage environment:
Temperature: 4 °C (39 °F) to +40 °C (104 °F)
Relative humidity: < 85%
Sensors (depending on View monitor):
Radon
Particulate Matter
CO2
VOC
Temperature
Relative Humidity
Pressure
IAQ Sensor Specifications
Sensor sampling interval:
5 minutes
Sensor Resolution:
Temperature ∓ 0.1°C / F
Humidity ∓1%
Pressure ∓0.15hPa
Temperature sensor accuracy:
+/- 0.5C at 25C,
+/- 1.0C in 0-65C range
Initial calibration time:
VOC ~7 days
CO2 ~7 days
CO2 details:
NDIR Sensor (Non-Dispersive Infra-Red):
Measurement range 400–5000 ppm
Optimum Accuracy ±30ppm ±3% within 15 – 35°C / 60 - 95°F and 0 – 80%RH after initial calibration time
Particulate Matter (PM2.5) details:
Laser scattering based optical particle counter
Particle size detection range: 300 nm to 10 um
Range: 0~200 μg/m³
Measurement error (PM2.5): 0 ~100μg/m3, ±10μg/m3,100 ~200 μg/m3, ±10%. Calibrated with a GRIMM using cigarette smoke source
Radon Sensor Specifications
Radon sampling: Passive diffusion chamber
Detection method: Alpha spectrometry
Measurement range: 0 – 500 pCi/L / 0 – 20,000 Bq/m3
Accuracy/precision at 5.4 pCi/L / 200 Bq/m3 after several weeks of settling period: 7 day average ~ 10 %
After 2 months ~ 5 %