The Wave Plus measures:
Radon
Temperature
Humidity
CO2
VOCs
Air pressure
GENERAL SPECS of Wave Plus:
Operational Environment:
39°F to 104°F (4° C to 40° C);
below 85% humidity
away from heavy dust and direct sunlight
should not be used outdoors
Weight: 7.7oz (219 gr.) including batteries;
Dimensions: 4.7in (12cm) diameter x 1.4in (3.6 cm) height
Power: 2 AA batteries
Connectivity: Bluetooth & Airthings SmartLink
AIR QUALITY - SENSOR SPECIFICATIONS
Sensor sampling interval: 5 minutes
Sensor Accuracy:
Temperature ± 1° C / ± 1.8° F
Humidity ± 3%
Pressure ± 0.15hPa
Settling time:
VOC ~ 7 days
CO2 ~ 7 days
CO2 details:
NDIR Sensor (Non-Dispersive Infra-Red)
Measurement range: 400–5000 ppm
Optimum Accuracy: ±30ppm ±3% within 15 – 35°C (60 - 95°F) and 0 – 80%RH can be reached after multiple settling cycles on locations with natural indoor CO2 fluctuations
VOC details:
Metal Oxide MEMS
Measurement range: 0–10,000 ppb
RADON SENSOR SPECIFICATIONS
Radon sampling: Passive diffusion chamber
Detection method: Alpha spectrometry
Measurement range: 0 – 500 pCi/L
STANDARD DEVIATION
Accuracy/precision after 30 days of continuous measuring:
Typical σ for 7-day average is:
~ ± 10% at 200 Bq/m3 or 5.4 pCi/L
Typical σ after two months:
~ ± 5% at 200 Bq/m3 or 5.4 pCi/L